Heat Treated Endodontic Files Rotary Gold Pathfile Endo Flexible Dental Root Canal Instruments

Place of Origin P. R. China
Brand Name S&D
Certification TUV CE, ISO13485, ISO9001
Model Number #13/02, #16/02, #19/02
Minimum Order Quantity 100 Packs
Price Negotiable
Packaging Details 10packs/box, 180boxes/carton
Delivery Time 3~25 days
Payment Terms T/T, Western Union, MoneyGram, L/C, D/P, D/A
Supply Ability 500 packs per day

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Material Nickel Titanium Size #13-19/02
Length 21mm, 25mm, 31mm Surface Color Gold/Silver
Instrument Classification Class 2 Package 6pcs/pack
High Light

heat treated rotary files

,

heat treated endodontic files

,

pathfile endo

You can tick the products you need and communicate with us in the message board.
#13 #16 #19
2.5-3N/cm 2.5-3N/cm 2.5-3N/cm
300rpm 300rpm 300rpm
.02 .02 .02
Leave a Message
#13 #16 #19
Product Description

Dental Process With Heat-Treatment Gold Color Rotary Endo Files Pathfile Is Flexible For Searching Root Canal

 

S&D Pathfile

This is the dental file used catheterization of the root canal.

These instruments are to be used only in a clinical or hospital environment, by qualified users. Users are responsible for checking whether the product can be used for the purpose intended.

2.Main materials

1) Cutting Nickel Titanium(including nickel and chromium)

2) Shank: copper

 

Purpose of use and effect -efficacy

only be used in continue rotary with a designated drive system with original settings

 

Specifications

Under the provisions of ISO 13485 performance test, product durability for twisting and bending must exceed specified value of our standard.

#13 02
#16 02
#19 02

 

Method of manipulating or method of use

Use at constant rotation at a speed of 300 rpm

 

Precautions for use

1.To prevent infection, sterilize the product by autoclave and make sure sterilization is completed before using .

2. Choose the most appropriative type for each case and follow the general method.

3.Before using, make sure the instruments outside of oral cavity that there are no deformations, scratches and cracks .

4. If the head of product is thin, long or large, there are possibilities for breaking or twisting. Because of this, be sure to avoid using unreasonable angle and excessive pressure.

5.Wear safety glasses to protect your eyes from damage. Also, wear a dust protective mask to prevent inhaling dust .

6.A chain, string, or other instrument shall be attached to the hole through the shank to prevent it from falling into the mouth.

7. A rubber dam or gauze screen should be used to prevent accidental ingestion and aspiration. Patients with a high likelihood of accidental ingestion or aspiration should not be treated in a horizontal position and should be treated in a seated position whenever possible.

8. Do not use this instrument for any purposes except for listed applications above.

9.Only for use by dentists.

10.This product should be treated as medical waste when disposed.

11.Dispose the product if damaged or contaminated .

12.After using, wash it with medical cleaning agent and brush, then wash away foreign substances like adherent body fluids and body tissues.

13.Avoid using unreasonable angle and excessive pressure.

14. This product has possibility that be corrosive if sunk into NaOCl, EDTA and etc . for a long time.

 

Storages and duration of use

1. Avoid storing at high temperature, humidity and direct sunlight.

Keep liquids away. Store it at room temperature.

2. Do not damage or make a pinhole to packaging materials.

3. The product is subject to be improved without previous notice. Enforce

the first-in first-out method for stock management.

4. Do not store the product under a germicidal lamp to avoid deterioration.

 

Maintenances and inspections

Sterilize this product by autoclave under established method and term for each use.

Method of sterilization:

Put this product in a sterilization pack (or foil) and place it on a sterilization tray, or files stand for autoclave sterilization with reference to the following terms.

Terms for sterilization:

term(1) temperature: 134degrees Celsius time: 15 minutes or more

2.Do not use high pressure steam sterilizer which heats more than 200 degrees Celsius including drying process .

 

Instruction of using 

1) Establish a manual Glide Path with stainless steel K-File # 008, # 010.

2) Identify the working length with the # 010 K-File

3) Use the PathFile # 013 (P1) to working length.

4) Use the PathFile # 016 (P2) to working length.

5) Use the PathFile # 019 (P3) to working length

6) Irrigate in each step.

10) Before starting the canal shaping with NiTi rotary files (or another system), confirm your working length with a K-File # 015